<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-10 15-46-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 61 dBuV SANDELS
Pilot RDS Phase Difference
4.6 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 71 kHz 16465 11,0538
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,1 dBr 4,78 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 71 kHz MIN: 10 kHz % above 76 kHz: 11,0538 Acquired: 2025/03/10 15.45.06 Total samples: 16465 Equivalent time: 0:13:43 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 6,4 dBr MIN: 3,1 dBr AVE: 4,78 dBr % above 12,2 dBr: 0,0 Last value: 3,8 dBr (2025/03/10 15.45.06) 15.32 15.34 15.36 15.38 15.40 15.42 15.44 0 2 4 6 Pm [dBr]